Download e-book for kindle: Minimizing Incisions and Maximizing Outcomes in Cataract by I. Howard Fine, Jorge Alio, Mark Packer (auth.), Jorge L.

By I. Howard Fine, Jorge Alio, Mark Packer (auth.), Jorge L. Alió MD, PhD, I. Howard Fine MD (eds.)

ISBN-10: 3642028616

ISBN-13: 9783642028618

Many ophthalmologists are within the transition from the normal cataract surgical procedure strategy to the hot minimally incision cataract surgical procedure (MICS) method. they're within the want of up to date details on the way to make this transition easily. during this publication, world-renowned opinion leaders current updated details at the new and fast-developing tendencies in cataract surgical procedure. It displays the cutting-edge of microincisional cataract surgical procedure with the idea that of minimizing incision. It deals all worthwhile details at the new expertise in addition to at the surgical method. extra, it demonstrates the way to deal with tough cataract instances in addition to new intraocular lenses.

Show description

Read Online or Download Minimizing Incisions and Maximizing Outcomes in Cataract Surgery PDF

Best ophthalmology books

Download e-book for iPad: Ophthalmology: Investigation and Examination Techniques by Bruce James MA DM FRCS FRCOphth, Larry Benjamin FRCS

Transparent, concise, and medical, this certain reference deals a finished evaluate of the fundamental concepts wanted for ocular exam and analysis. Abundantly illustrated, it offers the rules of every strategy, presents information on determining the ideal method, explains tips on how to practice them, bargains examples of while each one strategy will be used, and lists their universal symptoms and strength pitfalls.

Get 2011-2012 Basic and Clinical Science Course, Section 5: PDF

Offers a symptom-driven method of the analysis and remedy of significant neuro-ophthalmic stipulations. With the focal point at the sufferer, this ebook emphasizes exam and acceptable adjunctive reviews, together with a dialogue of diagnostic imaging modalities, and leads the reader during the occasionally sophisticated manifestations of neuro-ophthalmic ailment to anatomical localization of lesions and definitive analysis.

New PDF release: Vitreoretinal Surgery: Strategies and Tactics

This booklet is phenomenal in explaining not just whilst and the way but additionally why vitrectomy is played – an extra concentration that would support trainee surgeons to strengthen their very own serious pondering. Uniquely, the book’s first half describes “the lifetime of the vitreoretinal health practitioner” to aid citizens come to a decision even if the sphere is certainly compatible for them, and if sure, how they could chart their very own direction within the absence of a proper fellowship software.

New PDF release: Handbook of glaucoma

Glaucoma isn't a unmarried affliction that responds to a unmarried remedy. a number of scientific entities is concerned, together with either ocular and systemic stipulations. Glaucoma is tough to diagnose, and that makes its remedy much more tough. during this quantity, the authors try to alleviate confusion approximately glaucoma.

Extra info for Minimizing Incisions and Maximizing Outcomes in Cataract Surgery

Sample text

Take Home Pearls ß Pressured fluidics, new phaco tip and new irriß ß gation instruments are necessary. Combined procedures are possible with greater control for treatment of multiple diseases such as glaucoma and vitreous. 6 mm is mandatory. References 1. Agarwal A, Agarwal C, Agarwal AT. The Phakonit Thinoptx IOL. In Agarwals A (ed) Textbook Presbyopia. Slack, USA, 2002; pp 187–194 2. Pandey S, Wener L, Agarwal A, Agarwal S, Agarwal At, Hoyos J. 0 mm incision with implantation of the Thinoptx rollable IOL.

5 mm. 3 mm (Cat. No. 1719, Oasis Medical) (Fig. 30). 7 mm. 7 mm MICS, but Fig. 32 Fine/Olsen irrigating chopper 20G (Storz, Bausch & Lomb) Fig. 33 Olson Cannula irrigating chopper 21G (Rhein Medical Inc) irrigation and aspiration cannulas are not fitted. 7 mm MICS through 1 mm incision (Fig. 31). The decreased thickness of the walls and the appropriate internal profile gives an opportunity to achieve the required inflow of the fluid into the anterior chamber. Stinger irrigating chopper 22G also has a narrow edge at the end, this allows to divide and conduct the masses into the aspiration cannula.

Stable conditions The appropriate combination of these conditions and the proper application of the instruments and machine setting make sub-1 mm surgery possible. 7 mm MICS are the standard procedures performed by authors. The right use of the tools and the adequate setup of the machine fluidics help to operate all grades of cataracts, including complicated cataracts. The surgery is more controllable if properly performed. By choosing the right instruments and fluidics, it is possible to get all types of cataracts, even complicated ones, through sub-1 mm incision.

Download PDF sample

Minimizing Incisions and Maximizing Outcomes in Cataract Surgery by I. Howard Fine, Jorge Alio, Mark Packer (auth.), Jorge L. Alió MD, PhD, I. Howard Fine MD (eds.)


by Jeff
4.4

Rated 4.41 of 5 – based on 28 votes